a2scan
two-motor scan
SYNOPSIS
a2scan motor1 start1 end1 motor2 start2 end2 intervals time
DESCRIPTION
a2scan scans two motors, as specified by motor1 and motor2. Each motor moves the same number of intervals with starting and ending positions given by start1 and end1, start2 and end2, respectively. The step size for each motor is (start-end)/intervals. The number of data points collected will be intervals+1. Count time is given by time, which if positive, specifies seconds and if negative, specifies monitor counts.
EXAMPLE
a2scan th 0 10 phi 0 20 20 10